单位:[1]Division of Cardiology,Department of Internal Medicine,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China.内科学系大内科心血管内科华中科技大学同济医学院附属同济医院内科门诊[2]Hubei Key Laboratory of Genetics and Molecular Mechanisms of Cardiologic Disorders, Wuhan 430030, China.
Global longitudinal strain (GLS) is a sensitive and reproducible predictive factor in patients with ischemic heart disease (IHD), although its correlation with exercise tolerance is unknown. We aimed to identify the correlation between global longitudinal strain (GLS) and cardiopulmonary exercise testing (CPX) parameters and assess the prognostic implications and accuracy of GLS in predicting exercise intolerance in populations with ischemic heart disease (IHD) using CPET criteria.Prospectively, 108 patients with IHD underwent CPX and 2D speckle-tracking echocardiography. Correlation between GLS and multiple CPX variables was assessed using Spearman's correlation analysis and univariate regression analysis. A receiver operating characteristic (ROC) curve analysis was performed on GLS to detect exercise intolerance.GLS was correlated with peak oxygen uptake (peak VO2; r = -0.438, p = 0.000), %PPeak VO2 (-0.369, p = 0.000), peak metabolic equivalents (METs@peak; r = -0.438, p < 0.01), and the minute ventilation-carbon dioxide production (VE/VCO2) slope (r = 0.257, p < 0.01). Weak-to-moderate correlations were also identified for the respiratory exchange rate at the anaerobic threshold (RER@AT), end-tidal carbon dioxide at the anaerobic threshold (PETCO2@AT), oxygen consumption at the anaerobic threshold (VO2@AT), carbon dioxide production at the anaerobic threshold (VCO2@AT), and metabolic equivalents at the anaerobic threshold (METs@AT; p < 0.01). On multivariate analysis, the results showed that age, the BMI, and GLS are independent predictors for reduced exercise capacity in patients with IHD (p < 0.01). The area under the ROC curve value of GLS for identifying patients with a peak VO2 of <14 mL/kg/min was 0.73 (p = 0.000).As a sensitive echocardiographic assessment of patients with ischemic heart disease, global longitudinal strain is an independent predictor of reduced exercise capacity and has a sensitivity of 74.2% and a specificity of 66.7% to detect exercise intolerance.
第一作者单位:[1]Division of Cardiology,Department of Internal Medicine,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
Zhang Sisi,Liu Yujian,Jiang Luying,et al.Diagnostic Accuracy of Global Longitudinal Strain for Detecting Exercise Intolerance in Patients with Ischemic Heart Disease[J].JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE.2023,10(1):10.doi:10.3390/jcdd10010010.
APA:
Zhang Sisi,Liu Yujian,Jiang Luying,Wang Zhaozhao,Liu Wanjun&Zuo Houjuan.(2023).Diagnostic Accuracy of Global Longitudinal Strain for Detecting Exercise Intolerance in Patients with Ischemic Heart Disease.JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE,10,(1)
MLA:
Zhang Sisi,et al."Diagnostic Accuracy of Global Longitudinal Strain for Detecting Exercise Intolerance in Patients with Ischemic Heart Disease".JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE 10..1(2023)