高级检索
当前位置: 首页 > 详情页

Diagnostic Accuracy of Global Longitudinal Strain for Detecting Exercise Intolerance in Patients with Ischemic Heart Disease

| 导出 | |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Division of Cardiology,Department of Internal Medicine,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China. [2]Hubei Key Laboratory of Genetics and Molecular Mechanisms of Cardiologic Disorders, Wuhan 430030, China.
出处:
ISSN:

摘要:
Global longitudinal strain (GLS) is a sensitive and reproducible predictive factor in patients with ischemic heart disease (IHD), although its correlation with exercise tolerance is unknown. We aimed to identify the correlation between global longitudinal strain (GLS) and cardiopulmonary exercise testing (CPX) parameters and assess the prognostic implications and accuracy of GLS in predicting exercise intolerance in populations with ischemic heart disease (IHD) using CPET criteria.Prospectively, 108 patients with IHD underwent CPX and 2D speckle-tracking echocardiography. Correlation between GLS and multiple CPX variables was assessed using Spearman's correlation analysis and univariate regression analysis. A receiver operating characteristic (ROC) curve analysis was performed on GLS to detect exercise intolerance.GLS was correlated with peak oxygen uptake (peak VO2; r = -0.438, p = 0.000), %PPeak VO2 (-0.369, p = 0.000), peak metabolic equivalents (METs@peak; r = -0.438, p < 0.01), and the minute ventilation-carbon dioxide production (VE/VCO2) slope (r = 0.257, p < 0.01). Weak-to-moderate correlations were also identified for the respiratory exchange rate at the anaerobic threshold (RER@AT), end-tidal carbon dioxide at the anaerobic threshold (PETCO2@AT), oxygen consumption at the anaerobic threshold (VO2@AT), carbon dioxide production at the anaerobic threshold (VCO2@AT), and metabolic equivalents at the anaerobic threshold (METs@AT; p < 0.01). On multivariate analysis, the results showed that age, the BMI, and GLS are independent predictors for reduced exercise capacity in patients with IHD (p < 0.01). The area under the ROC curve value of GLS for identifying patients with a peak VO2 of <14 mL/kg/min was 0.73 (p = 0.000).As a sensitive echocardiographic assessment of patients with ischemic heart disease, global longitudinal strain is an independent predictor of reduced exercise capacity and has a sensitivity of 74.2% and a specificity of 66.7% to detect exercise intolerance.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 3 区 医学
小类 | 3 区 心脏和心血管系统
最新[2025]版:
大类 | 3 区 医学
小类 | 4 区 心脏和心血管系统
JCR分区:
出版当年[2021]版:
Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q2 CARDIAC & CARDIOVASCULAR SYSTEMS

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者单位: [1]Division of Cardiology,Department of Internal Medicine,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:0 总访问量:413 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)