高级检索
当前位置: 首页 > 详情页

Fabrication of a Disposable Electrochemical Immunosensor Based on Nanochannel Array Modified Electrodes and Gated Electrochemical Signals for Sensitive Determination of C-Reactive Protein

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Shanxi Med Univ, Shanxi Bethune Hosp, Tongji Shanxi Hosp, Shanxi Acad Med Sci,Hosp 3, Taiyuan 030032, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Wuhan 430030, Peoples R China [3]Zhejiang Sci Tech Univ, Dept Chem, Key Lab Surface & Interface Sci Polymer Mat Zheji, Hangzhou 310018, Peoples R China
出处:
ISSN:

关键词: electrochemical immunosensor disposable and integrated electrode vertically-ordered mesoporous silica-nanochannel film screen-printed carbon electrode c-reactive protein

摘要:
Sensitive determination of C-reactive protein (CRP) is of great significance because it is an early indicator of inflammation in cardiovascular disease and acute myocardial infarction. A disposable electrode with an integrated three-electrode system (working, reference, and counter electrodes) has great potential in the detection of biomarkers. In this work, an electrochemical immunosensing platform was fabricated on disposable and integrated screen-printed carbon electrode (SPCE) by introducing nanochannel arrays and gated electrochemical signals, which can achieve the sensitive detection of CRP in serum. To introduce active reactive groups for the fabrication of immuno-recognitive interface, vertically-ordered mesoporous silica-nanochannel film (VMSF) with rich amino groups (NH2-VMSF) was rapidly grown by electrochemical assisted self-assembly (EASA). The electrochemically reduced graphene oxide (ErGO) synthesized in situ during the growth of NH2-VMSF was used as a conductive adhesive glue to achieve stable bonding of the nanochannel array (NH2-VMSF/ErGO/SPCE). After the amino group on the outer surface of NH2-VMSF reacted with bifunctional glutaraldehyde (GA/NH2-VMSF/ErGO/SPCE), the converted aldehyde surface was applied for covalent immobilization of the recognitive antibody (Ab) followed with the blocking of the non-specific sites. The fabricated immunosensor, Ab/GA/NH2-VMSF/ErGO/SPCE, enables sensitive detection of CRP in the range from 10 pg/mL to 100 ng/mL with low limit of detection (LOD, 8 pg/mL, S/N = 3). The immunosensor possessed high selectivity and can realize reliable determination of CRP in human serum.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 材料科学
小类 | 3 区 化学综合 3 区 纳米科技 3 区 材料科学:综合 3 区 物理:应用
最新[2025]版:
大类 | 3 区 材料科学
小类 | 3 区 化学:综合 3 区 材料科学:综合 3 区 物理:应用 4 区 纳米科技
JCR分区:
出版当年[2020]版:
Q1 PHYSICS, APPLIED Q2 CHEMISTRY, MULTIDISCIPLINARY Q2 MATERIALS SCIENCE, MULTIDISCIPLINARY Q2 NANOSCIENCE & NANOTECHNOLOGY
最新[2023]版:
Q2 CHEMISTRY, MULTIDISCIPLINARY Q2 MATERIALS SCIENCE, MULTIDISCIPLINARY Q2 NANOSCIENCE & NANOTECHNOLOGY Q2 PHYSICS, APPLIED

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Shanxi Med Univ, Shanxi Bethune Hosp, Tongji Shanxi Hosp, Shanxi Acad Med Sci,Hosp 3, Taiyuan 030032, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Wuhan 430030, Peoples R China
通讯作者:
通讯机构: [1]Shanxi Med Univ, Shanxi Bethune Hosp, Tongji Shanxi Hosp, Shanxi Acad Med Sci,Hosp 3, Taiyuan 030032, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Wuhan 430030, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:589 今日访问量:0 总访问量:441 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)