INFRARED VEIN IMAGING FOR INSERTION OF PERIPHERAL INTRAVENOUS CATHETER FOR PATIENTS REQUIRING ISOLATION FOR SEVERE ACUTE RESPIRATORY SYNDROME CORONAVIRUS 2 INFECTION: A NONRANDOMIZED CLINICAL TRIAL

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ SSCI

单位: [1]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Rheumatol & Immunol,Wuhan,Peoples R China [2]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Gastrointestinal Surg,Wuhan,Peoples R China [3]Huazhong Univ Sci & Technol,Key Lab Organ Transplantat,Minist Educ,Ctr Biomed Res,Tongji Med Coll,Tongji Hosp,1095 Jiefang Ave,Wuhan 430030,Peoples R China [4]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Minist Hlth,1095 Jiefang Ave,Wuhan 430030,Peoples R China [5]Huazhong Univ Sci & Technol,Tongji Hosp,Dept Internal Med,Tongji Med Coll,1095 Jiefang Ave,Wuhan 430030,Peoples R China
出处:
ISSN:

关键词: COVID-19 Infrared vein visualizer Peripheral intravenous catheter insertion

摘要:
Introduction: Establishing intravenous access is essential but may be difficult to achieve for patients requiring isolation for severe acute respiratory syndrome coronavirus 2 infection. This study aimed to investigate the effectiveness of an infrared vein visualizer on peripheral intravenous catheter therapy in patients with coronavirus disease 2019. Methods: A nonrandomized clinical trial was performed. In total, 122 patients with coronavirus disease 2019 who required peripheral intravenous cannulation were divided into 2 groups with 60 in the control group and 62 in the intervention group. A conventional veni puncture method was applied to the control group, whereas an infrared vein imaging device was applied in the intervention group. The first attempt success rate, total procedure time, and patients' satisfaction score were compared between the 2 groups using chi-square, t test, and z test (also known as Mann-Whitney U test) statistics. Results: The first attempt success rate in the intervention group was significantly higher than that of control group (91.94% vs 76.67%, chi(2) = 5.41, P = .02). The procedure time was shorter in the intervention group (mean [SD], 211.44 [68.58] seconds vs 388.27 [88.97] seconds, t = 12.27, P < .001). Patients from the intervention group experienced a higher degree of satisfaction (7.5 vs 6, z = -3.31, P < .001). Discussion: Peripheral intravenous catheter insertion assisted by an infrared vein visualizer could improve the first attempt success rate of venipuncture, shorten the procedure time, and increase patients' satisfaction.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 3 区 急救医学 3 区 护理
最新[2025]版:
大类 | 4 区 医学
小类 | 3 区 护理 4 区 急救医学
JCR分区:
出版当年[2020]版:
Q3 NURSING Q3 EMERGENCY MEDICINE
最新[2023]版:
Q2 EMERGENCY MEDICINE Q2 NURSING

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Rheumatol & Immunol,Wuhan,Peoples R China
通讯作者:
通讯机构: [3]Huazhong Univ Sci & Technol,Key Lab Organ Transplantat,Minist Educ,Ctr Biomed Res,Tongji Med Coll,Tongji Hosp,1095 Jiefang Ave,Wuhan 430030,Peoples R China [4]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Minist Hlth,1095 Jiefang Ave,Wuhan 430030,Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:428 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)